GBICS · Dubai · UAE

AI & Data Centre Connectivity in the UAE

Build the right connection for your next deployment.

Source SFP transceivers in Dubai, QSFP optical modules and data centre cabling for enterprise networks, cloud platforms and AI infrastructure. Bring GBICS your equipment models and link requirements for a focused compatibility review and project quote.

UAE stock and dispatch options · Model-specific compatibility review · Warranty terms confirmed with your quote

Image placement: use a 1200 × 900 hardware render showing module labels, connectors and an MPO cable on a clean background.

For buyers and project managers

Enterprise networking hardware for every layer of your data centre

From server access to spine uplinks, a successful rollout starts with a consistent bill of materials. GBICS helps you specify optics and cable assemblies around port requirements, rack distances and the equipment already in your network.

AI cluster connectivity

Plan high-bandwidth links between GPU servers, network adapters and switches. For 400G QSFP-DD or 800G OSFP requirements, confirm host support, lane configuration, FEC, module power and airflow before choosing a SKU.

Enterprise & cloud networks

Match 10G SFP+, 25G SFP28, 40G QSFP+ and 100G QSFP28 options to access, aggregation and uplink roles. Build around your current fibre plant and a clear migration path.

Data centre cabling

Specify DAC, AOC, LC patch leads and MPO/MTP assemblies by distance and connector requirements. Confirm polarity, fibre count, connector gender and polish for parallel optical links.

One project list. Clear procurement decisions.

Send a BOQ covering transceivers, cable lengths, quantities and equipment models. Ask GBICS to confirm compatible options, available UAE stock, delivery estimates and applicable warranty terms before purchase. This helps procurement teams compare like-for-like specifications and avoid substitutions that do not meet the link design.

Email your BOQ

Choose the right medium for each link

DAC: short rack connections

Direct attach copper cable assemblies are a practical starting point for short server-to-switch links. Check the exact length, cable gauge, bend radius and passive or active host support.

AOC: integrated optical cabling

Active optical cables combine optics and fibre in a fixed assembly. Confirm both end types, vendor coding and supported reach when cabling between racks.

Optics + fibre: modular links

Separate optical modules and fibre support structured cabling and replaceable components. Select multimode or single-mode fibre around the optical standard and required distance.

For AI fabrics, identify whether the ports use Ethernet or InfiniBand. A matching speed label and connector do not establish protocol compatibility. Specify adapters and cables supported by the actual platform.

Engineering reference

SFP & QSFP optical module comparison

Use these representative Ethernet standards to narrow the design. Reach is the stated standard or representative module limit under the specified fibre conditions, rather than a guarantee for an installed channel. Confirm insertion loss, connector count and the selected module datasheet.

Representative optical link specifications
Form factor / standardNominal rateMaximum listed reachFibreWavelengthConnectorCompatibility
SFP+ / 10GBASE-SR10G300 m OM3 / 400 m OM4MMF850 nmDuplex LCExact host and software review required
SFP+ / 10GBASE-LR10G10 kmSMF1310 nmDuplex LCExact host and software review required
QSFP+ / 40GBASE-SR440G100 m OM3 / 150 m OM4MMF850 nmMPO-12Exact host and software review required
QSFP28 / 100GBASE-SR4100G70 m OM3 / 100 m OM4MMF850 nmMPO-12Exact host and software review required
QSFP28 / 100GBASE-LR4100G10 kmSMF4 LAN-WDM wavelengths near 1310 nmDuplex LCExact host and software review required
QSFP-DD / 400GBASE-DR4400G500 mSMF1310 nmMPO-12 / APCExact host and software review required

MMF: multimode fibre. SMF: single-mode fibre. LR4 uses wavelength multiplexing. These entries describe optical standards, not confirmed GBICS inventory. Exact part-number specifications take precedence.

What changes at 400G and 800G?

Higher-speed links require attention to electrical and optical lane mapping, breakout support, FEC and thermal limits. QSFP-DD and OSFP are different mechanical formats; use the format your host supports. A 400G DR4 design may support four 100G DR links only when both endpoints and the breakout configuration are supported.

For 800G, request the precise optical standard and module datasheet rather than selecting by speed alone. Fibre count, connector layout and reach vary by implementation.

Compare nominal port capacity

This chart shows the specified Ethernet port rates used in planning. It is not a measured throughput, latency or application-performance benchmark.

10G Ethernet
10G
40G Ethernet
40G
100G Ethernet
100G
400G Ethernet
400G
800G Ethernet
800G
Linear scale: 800 Gb/s is full width. Actual usable throughput depends on traffic, protocol overhead, switching, congestion and the end-to-end system.

Specify before you deploy

OEM coding and optical compatibility: check the complete link

For Cisco, Juniper, Arista, HPE, Dell, Huawei, Fortinet or NVIDIA equipment, provide the exact model and software release. Vendor coding is one part of compatibility; port capability, electrical interface, optical standard and firmware support must also align. Brand names identify equipment requirements and do not imply vendor authorization.

1. Host requirements

  • Switch, router or NIC model
  • Port type and supported speed
  • Software and firmware versions
  • Module power and cooling limits

2. Optical channel

  • Standard and link distance
  • OM3/OM4 or OS2 fibre
  • LC or MPO connector details
  • Polarity, polish and loss budget

3. Operational settings

  • FEC mode and breakout mapping
  • Protocol and lane configuration
  • DOM/DDM visibility where supported
  • Validation and acceptance criteria

Acceptance testing for reliable deployment

Define your acceptance checks in the purchase specification: host recognition, link establishment, DOM readings where supported, error counters and sustained traffic under the intended settings. Request the available compatibility evidence and test documentation for the supplied part numbers.

Replace with an engineering diagram labeling port speeds, uplink quantities, cable types and rack distances. Use a responsive SVG or a 1600 × 800 image with equivalent alt text.

Plan capacity, resilience and procurement together

Capacity planning

Size uplinks against traffic demand and oversubscription targets. Faster optics expand link capacity, but application performance also depends on the network design and server resources.

Operational resilience

Document redundant paths and spare-module requirements. Keep consistent part numbers and approved replacements to make future maintenance easier.

Regional fulfilment

GBICS advertises UAE stock, same-day dispatch and lifetime warranty. Confirm availability, cutoff times, shipping estimates and item-specific warranty terms in your quote.

AI & Data Centre FAQs

Which optical transceivers should I choose for an AI data centre?

Start with the switch or NIC model, supported port speed and distance. Then match the optical standard, fibre, connector, FEC and cooling requirements. GBICS can review a bill of quantities before recommending specific part numbers.

Are OEM-compatible transceivers compatible with every switch?

No. Compatibility depends on the exact host model, software release, port configuration and module implementation. OEM coding helps the host identify a module but does not establish universal compatibility. Request a model-specific review before ordering.

What is the difference between DAC, AOC and optical transceivers?

DAC is a copper cable assembly commonly used for short rack links. AOC is a fixed optical cable assembly. Separate optical transceivers and fibre cables allow modular cabling and a wider choice of reach. Supported lengths and power depend on the selected product.

Can I use QSFP-DD and OSFP modules interchangeably?

QSFP-DD and OSFP are different mechanical form factors and are not directly interchangeable. Select the form factor supported by your equipment and confirm module power, cooling, electrical lanes and firmware support.

Does GBICS supply MPO and MTP cabling in the UAE?

Send GBICS your MPO or MTP cabling requirements, including fibre type, fibre count, length, polarity, gender and polish. MTP is a branded MPO connector implementation; the complete connector and cable specification must match the link.

Can GBICS arrange fast delivery and warranty support?

GBICS advertises UAE stock, same-day dispatch and lifetime warranty. Ask for confirmation of stock, dispatch cutoff, destination delivery estimate and warranty eligibility for each quoted item.

How do I request an enterprise quote?

Email store@gbics.ae with your company details, switch or NIC models, part numbers, quantities, link distances, fibre type and delivery location. Include a BOQ and target deployment date where available.

Your next deployment starts here

Turn your AI infrastructure requirements into a clear enterprise quote

Share your equipment models, optical speeds, cable specifications and deployment schedule. Ask GBICS to confirm compatible part numbers, pricing, stock and delivery for your UAE project.

Request a custom enterprise quote

Email store@gbics.ae · Attach your BOQ in your email application.